The COSMOSIL 5C18-PAQ is a new member of our C18 column family which already includes the monomeric type MS-II and the polymeric type AR-II. This new column maintains stable retention time even in 100% aqueous mobile phases. The new polymeric linking style gives this column a strong acidic resistance so that it is compatible with mobile phases of acidic pH that can permanently damage conventional octadecyl stationary phases. This type is especially good for separation of hydrophilic compounds.
The figure shows the change of retention time for thymine with 100% aqueous mobile phase (20 mmol/l phosphate buffer pH7). The sample was analyzed 4 times. Flow of mobile phase was then stopped for 1 hour. The sample was analyzed under the same condition again after 1 hour. The conventional C18 column showed change of retention time, but COSMOSIL 5C18-PAQ maintained stable retention time.


| Condition | |
|---|---|
| Column Size | 4.6 mm I.D. x 250 mm |
| Mobile Phase | 20 mmol/l Phosphoric Acid |
| Flow rate | 1.0ml/min |
| Temperature | 30°C |
| Detection | UV 210 nm 0.16AUFS |
| Sample |
|

| Condition | |
|---|---|
| Column Size | 4.6 mm I.D. x 250 mm |
| Mobile Phase | 20 mmol/l Phosphoric Acid |
| Flow Rate | 1.0ml/min |
| Temperature | 30°C |
| Detection | UV 210 nm 0.16AUFS |
| Sample |
|

| Condition | |
|---|---|
| Column Size | 4.6 mm I.D. x 150 mm |
| Mobile Phase | 20 mmol/l Phosphate Buffer (pH7) |
| Flow Rate | 1.0 ml/min |
| Temperature | 30°C |
| Detection | UV 254 nm 0.16AUFS |
| Sample |
|

| Condition | |
|---|---|
| Column Size | 4.6 mm I.D. x 250 mm |
| Mobile Phase | 20 mmol/l Phosphate Buffer (pH7) |
| Flow Rate | 1.0 ml/min |
| Temperature | 30°C |
| Detection | UV 260 nm 0.16 AUFS |
| Sample |
|

| Condition | |
|---|---|
| Column Size | 4.6 mm I.D. x 250 mm mm |
| Mobile Phase | 20 mmol/l Phosphoric Acid |
| Flow Rate | 1.0 ml/min |
| Temperature | 30°C |
| Detection | UV 245 nm 0.16 AUFS |
| Sample | Ascorbic Acid (Vitamin C) 0.1 µg |


| Condition | |
|---|---|
| Column Size | 4.6 mm I.D. x 150 mm |
| Mobile Phase | Acetonitrile : Methanol : Water = 8 : 4 : 88 |
| Flow Rate | 1.0 ml/min |
| Temperature | 30°C |
| Detection | UV 210 nm 0.064 AUFS |
| Sample | 10.5 MPa |
| Product Name | Size | Product No. |
|---|---|---|
| COSMOSIL 5C18-PAQ Guard Column | ||
| 4.6 mm I.D. x 10 mm | 02484-91 | |
| 10 mm I.D. x 20 mm | 34457-61 | |
| 20 mm I.D. x 20 mm | 05803-11 | |
| 20 mm I.D. x 50 mm | 05804-01 | |
| 28 mm I.D. x 50 mm | 34455-81 | |
| COSMOSIL 5C18-PAQ Packed Column | ||
| 1.0 mm I.D. x 50 mm | 05792-61 | |
| 1.0 mm I.D. x 150 mm | 05793-51 | |
| 2.0 mm I.D. x 30 mm | 05878-51 | |
| 2.0 mm I.D. x 50 mm | 05794-41 | |
| 2.0 mm I.D. x 100 mm | 05470-71 | |
| 2.0 mm I.D. x 150 mm | 34449-71 | |
| 2.0 mm I.D. x 250 mm | 05795-31 | |
| 3.0 mm I.D. x 100 mm | 05796-21 | |
| 3.0 mm I.D. x 150 mm | 05797-11 | |
| 3.0 mm I.D. x 250 mm | 05798-01 | |
| 4.6 mm I.D. x 30 mm | 05879-41 | |
| 4.6 mm I.D. x 50 mm | 34451-21 | |
| 4.6 mm I.D. x 100 mm | 05799-91 | |
| 4.6 mm I.D. x 150 mm | 02486-71 | |
| 4.6 mm I.D. x 250 mm | 02485-81 | |
| 6.0 mm I.D. x 150 mm | 34419-61 | |
| 6.0 mm I.D. x 250 mm | 05800-41 | |
| 10 mm I.D. x 50 mm | 05801-31 | |
| 10 mm I.D. x 150 mm | 34466-41 | |
| 10 mm I.D. x 250 mm | 34376-21 | |
| 20 mm I.D. x 150 mm | 34476-11 | |
| 20 mm I.D. x 250 mm | 34373-51 | |
| 28 mm I.D. x 250 mm | 34456-71 |
| Product Name | Size | Product No. |
|---|---|---|
| COSMOSIL 15C18-PAQ Guard Column | ||
| 28 mm l.D. x 50 mm | 05887-31 | |
| 50 mm l.D. x 50 mm | 05889-11 | |
| COSMOSIL 15C18-PAQ Packed Column | ||
| 28 mm l.D. x 250 mm | 05888-21 | |
| 50 mm l.D. x 250 mm | 05890-71 | |
| 50 mm l.D. x 500 mm | 05891-61 |