COSMOSIL alkyl type columns also include stationary phases with packing materials of C22 (Dococyl group), C8 (Octadecyl group), C4(Butyl group) and TMS (Trimethyl group). The order of retention force by hydrophobicity of each packing material is C22=C18>C8>C4>TMS. The columns having lower hydrophobicity than C18 or C22 are effective for separation of high hydrophobic compounds and compounds with big difference in hydrophobic. Hydrophobicity of C22 is about the same as C18. However, stereoselectivity of C22 is higher than C18, and so C22 may provide better separation.
| Packing material | C22-AR-II | C18-MS-II | C8-MS | C4-MS | TMS-MS |
|---|---|---|---|---|---|
| Silica gel | high purity porous spherical silica | ||||
| Average particle size | 5 m | ||||
| Average pore size | approx. 120 | ||||
| Specific surface area | approx. 300 m2/g | ||||
| Stationary phase | dococyl group |
![]() octadecyl group |
![]() octyl group |
![]() butyl group |
trimethyl group |
| Bonding type | polymeric | monomeric | |||
| Main interaction | hydrophobic interaction | ||||
| End capping treatment | near-perfect treatment | ||||
| Carbon content | approx. 19% | approx. 16% | approx. 10% | approx. 7% | approx. 5% |
The shorter alkyl chain stationary phase shows shorter retention time for non-polar compounds such as benzene and toluene and longer retention for polar compounds such as acetophenone and benzoate.

| Condition | ||||
|---|---|---|---|---|
| Column size | 4.6 mm I.D. x 150 mm | Sample | 1. Acetophenone | 0.05 g |
| Mobile phase | methanol : water = 60 : 40 | 2. Methyl Benzoate | 0.5 g | |
| Flow rate | 1.0 ml/min | 3. Benzene | 2.0 g | |
| Temperature | 30°C | 4. Toluene | 2.0 g | |
| Detection | UV 254 nm | |||
| Product name | Size | Product No. |
|---|---|---|
| COSMOSIL 5C22-AR-II Guard Column | ||
| 4.6 mm I.D. x 10 mm | 04881-21 | |
| 10 mm I.D. x 20 mm | 05554-81 | |
| COSMOSIL 5C22-AR-II Packed Column |
||
| 4.6 mm I.D. x 50 mm | 05848-41 | |
| 4.6 mm I.D. x 100 mm | 05849-31 | |
| 4.6 mm I.D. x 150 mm | 04598-51 | |
| 4.6 mm I.D. x 250 mm | 04599-41 | |
| 6.0 mm I.D. x 150 mm | 05850-91 | |
| 6.0 mm I.D. x 250 mm | 05851-81 | |
| 10 mm I.D. x 250 mm | 04969-91 | |
| 20 mm I.D. x 250 mm | 05183-41 |
| Product name | Size | Product No. |
|---|---|---|
| COSMOSIL 5C8-MS Guard Column | ||
| 4.6 mm I.D. x 10 mm | 38151-31 | |
| 10 mm I.D. x 20 mm | 38152-21 | |
| COSMOSIL 5C8-MS Packed Column | ||
| 4.6 mm I.D. x 50 mm | 38153-11 | |
| 4.6 mm I.D. x 100 mm | 38154-01 | |
| 4.6 mm I.D. x 150 mm | 38155-91 | |
| 4.6 mm I.D. x 250 mm | 38156-81 | |
| 6.0 mm I.D. x 150 mm | 38157-71 | |
| 6.0 mm I.D. x 250 mm | 38158-61 | |
| 10 mm I.D. x 250 mm | 38159-51 | |
| 20 mm I.D. x 250 mm | 38160-11 |
| Product name | Size | Product No. |
|---|---|---|
| COSMOSIL 5C4-MS Guard Column | ||
| 4.6 mm I.D. x 10 mm | 38161-01 | |
| 10 mm I.D. x 20 mm | 38162-91 | |
| COSMOSIL 5C4-MS Packed Column | ||
| 4.6 mm I.D. x 50 mm | 38163-81 | |
| 4.6 mm I.D. x 100 mm | 38164-71 | |
| 4.6 mm I.D. x 150 mm | 38165-61 | |
| 4.6 mm I.D. x 250 mm | 38166-51 | |
| 6.0 mm I.D. x 150 mm | 38167-41 | |
| 6.0 mm I.D. x 250 mm | 38168-31 | |
| 10 mm I.D. x 250 mm | 38169-21 | |
| 20 mm I.D. x 250 mm | 38170-81 |
| Product name | Size | Product No. |
|---|---|---|
| COSMOSIL 5TMS-MS Guard Column | ||
| 4.6 mm I.D. x 10 mm | 38171-71 | |
| 10 mm I.D. x 20 mm | 38172-61 | |
| COSMOSIL 5TMS-MS Packed Column | ||
| 4.6 mm I.D. x 50 mm | 38173-51 | |
| 4.6 mm I.D. x 100 mm | 38174-41 | |
| 4.6 mm I.D. x 150 mm | 38175-31 | |
| 4.6 mm I.D. x 250 mm | 38176-21 | |
| 6.0 mm I.D. x 150 mm | 38177-11 | |
| 6.0 mm I.D. x 250 mm | 38178-01 | |
| 10 mm I.D. x 250 mm | 38179-91 | |
| 20 mm I.D. x 250 mm | 38180-51 |